Anti Interference Dielectric Loss / Tan Delta Oil Analysis Relative Humidity <80%

  • 1
  • 2

Brand Name : RISING

Model Number : RSJS-III

Certification : ISO CE

Place of Origin : China

MOQ : 1 SET

Payment Terms : L/C, L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 500 SET PER Month

Packaging Details : Wooden package

High Voltage output : 0.5-10kV

Precision : tgδ: ± (reading×1.0%+0.08%)

Cx : ±(reading×1.5%+5pF)

Resolution : tgδ:0.01%Cx:1pF

Power Supply : AC 220V±10%50±1Hz

Harmonics : ≤3%

Service Condition : -15℃-50℃

Relative Humidity : <80%

External Dimension : 460(L)×335(W)×340(H)

Weight : 30 kg

Contact Now

Anti Interference Dielectric Loss / Tan Delta Oil Analysis Relative Humidity <80%

Product Description

Anti-interference dielectric loss measuring instrument is a high accuracy instrument for power plants, transformer substations and so on to conduct full-automatic measurement of dielectric loss tangent value and electric capacity of various high voltage electrical equipment. Frequency conversion technology ensures accurate measurement under strong electric field interference. Chinese menu operation has been added to the instrument which has one-through operation. Microcomputer can automatically complete the measurement of the entire process. It is the most ideal dielectric loss measuring equipment now. The instrument is applicable to measure tgδ and capacity of high-voltage electrical equipment in workshop, laboratory, scientific research institution, etc.; It makes insulating oil loss test more convenient, simple and accurate.

Tan Delta Tester Parameter

The instrument can test the following parameters and display them in figure:

Capacitance value of tested article CX is in pF or nF, 1nF=1,000pF.

Dielectric loss value of tested article tgδ is displayed with %.

Capacitance range

Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV

External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV

Resolution: Maximum 0.001pF, 4 valid figures.

Test current range 10μA~1A
Internal HV

Set voltage range: 0.5~10kV

Maximum output current: 200mA

Buck-bust method: continuous stepless regulation

Test frequency: 45, 50, 55 single frequency

45/55Hz automatic dual variable frequency

Frequency accuracy: ±0.01Hz

Input power supply 180V~270VAC, 50Hz/60Hz±1%, supplied by alternating current or generator
Computer interface Standard RS232 interface
Printer

WH-A7 mini-type thermal printer

Environment temperature -10°C~50°C

Product Tags:

automatic acid value tester

      

tan delta oil analysis

      
China Anti Interference Dielectric Loss / Tan Delta Oil Analysis Relative Humidity <80% wholesale

Anti Interference Dielectric Loss / Tan Delta Oil Analysis Relative Humidity <80% Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan Rising Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0